Answer:
(A-) Number of turns in secondary coil will be less than 125.
(B-) EXPLAIN- The voltage is to be lowered. The voltage will be reduced from 120 to 9 volts. As a result, a step down transformer will be used, indicating that the secondary coil's number of turns would be less than 125.
(C-) The number of turns on the secondary coil is 12.5
Explanation:
In electrical networks and transmission lines, a step-down transformer can be used in a number of ways.
Step down transformer formula-
[tex]V_s=\frac{N_s\times V_p}{N_p}[/tex]
We are given with the -
Primary voltage [tex]V_p[/tex] = 120V
Secondary voltage [tex]Vs=12V[/tex]
Number of primary turns [tex]N_p=125[/tex]
Since , the transformer ratio is given as -
[tex]\frac{N_s}{N_p} =\frac{V_s}{V_p}[/tex]
So, the number of turns on the secondary coil is - [tex]N_s=N_p\times\frac{V_p}{V_s}[/tex]
Putting , the given values -:
[tex]125\times\frac{12}{120}[/tex]
= 12.5
Therefore , the number of turns on secondary coil is 12.5 .